EasyManua.ls Logo

GW Instek PSW 30-72 - Output:protection:clear; Output:protection:tripped

GW Instek PSW 30-72
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PSW Series Programming Manual
62
Parameter
0
<NR1>Turns the output off when a software
trigger is generated.
OFF
Turns the output off when a software trigger
is generated.
1
<NR1>Turns the output on when a software
trigger is generated.
ON
Turns the output on when a software trigger
is generated.
Return parameter
<NR1>
Returns output trigger status of the
instrument.
OUTPut:PROTection:CLEar
Set
Description
Clears over-voltage, over-current and over-
temperature (OVP, OCP, OTP) protection circuits.
It also clears the shutdown protection circuit. The
AC failure protection cannot be cleared.
Syntax
OUTPut:PROTection:CLEar
OUTPut:PROTection:TRIPped
Query
Description
Returns the state of the protection circuits (OVP,
OCP, OTP).
Query Syntax
OUTPut:PROTection:TRIPped?
Return parameter
0
<NR1>Protection circuits are not tripped.
1
<NR1>Protection circuits are tripped.