8
b. Verify that the power module is in an acceptable temperature range. Dust buildup might
cause high temperature. If dust is accumulated on the power module, remove the dust.
Then remove and reinstall the power module. Execute the display power command to
verify that the power module has changed to Normal state. If the power module remains in
Fault state, go to step c.
c. Install the po
wer module into an empty power module slot. Then execute the display
power command to verify that the power module has changed to Normal state in the new
slot. If the power module remains in Fault state, replace the power module.
4. If the issue persists, contact H3C Support.
Newly installed power module failure
Symptom
A newly installed power module has failed.
Troubleshooting flowchart
Figure 3 Troubleshooting newly installed power module failure
Solution
To resolve the issue:
1. Identify the operating state of the power module.
<Sysname> display power
Slot 1:
PowerID State Mode Current(A) Voltage(V) Power(W)
1 Normal AC -- -- --
2 Absent -- -- -- --
If the power module is in Absent state, go to step 2. If the power module is in Fault state, go to
step 3.

Table of Contents

Other manuals for H3C S6520-SI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S6520-SI Series and is the answer not in the manual?

H3C S6520-SI Series Specifications

General IconGeneral
BrandH3C
ModelS6520-SI Series
CategorySwitch
LanguageEnglish

Related product manuals