37
[<c01d54a8>] hub_thread+0x88c/0xa64
[<c006ce28>] kthread+0xfc/0x12c
[<c00588d0>] do_exit+0x0/0x818
[<ffffffff>] 0xffffffff
[Sysname-probe]
4. Use the display diagnostic-information command to collect diagnostic information.
5. Save the information displayed in the previous steps.
6. Contact H3C Support.
High memory utilization
Symptom
The display memory command shows that the memory utilization of the device is higher than 60%
during a period of time (typically 30 minutes).
Troubleshooting flowchart
Figure 19 Troubleshooting high memory utilization
Solution
To resolve the issue:
1. Execute the display system internal kernel memory pool command multiple times
to identify the memory portions that show an unexceptionally utilization increase.
<Sysname> system-view
[Sysname] probe
[Sysname-probe] display system internal kernel memory pool slot 1
Active Number Size Align Slab Pg/Slab ASlabs NSlabs Name
0 0 80 0 32 1 0 0 ARP_MFFACL_Cachep
0 0 120 0 24 1 0 0 LFIB_IlmEntryCache2
0 0 216 0 15 1 0 0 mfib_source_route_cache
28 28 524240 0 1 128 28 28 kmalloc-524240
2 12 256 0 12 1 1 1 sgpool-16
48 51 32 0 51 1 1 1 SYNC_Chn_Object
0 0 64 0 36 1 0 0 LFIB_FTNSTAT_MplsBasCache

Table of Contents

Other manuals for H3C S6520-SI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S6520-SI Series and is the answer not in the manual?

H3C S6520-SI Series Specifications

General IconGeneral
BrandH3C
ModelS6520-SI Series
CategorySwitch
LanguageEnglish

Related product manuals