6
Switching the drive state
The storage controller supports the following drive states:
Unconfigured GoodThe drive is normal and can be used for RAID array or hot backup
configuration.
Unconfigured BadThe drive is faulty or has RAID array information remaining on it. If the
drive is faulty, replace the drive. If RAID array information remains on the drive, clear the RAID
array information.
HotspareThe drive is a hot spare drive.
JBOD/JBOD onlineJust a Bunch Of Disks. The drive is a passthrough or passthrough-like
drive and does not support RAID configuration. The passthrough drive is in JBOD online state
by default for the RAID-LSI-9560-LP-16i-8GB storage controller and in JBOD state for other
storage controllers.
To switch from Unconfigured Good state to Unconfigured Bad state:
1. On the storage controller configuration screen as shown in Figure 5, select Drive
Management and press Enter.
Figure 5 Storage controller configuration screen
2. On the screen as shown in Figure 6, select the target drive and press Enter.

Other manuals for H3C UniServer R4900 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C UniServer R4900 G3 and is the answer not in the manual?

H3C UniServer R4900 G3 Specifications

General IconGeneral
BrandH3C
ModelUniServer R4900 G3
CategoryServer
LanguageEnglish

Related product manuals