77
Figure 139 Selecting Initialization > Start FGI
NOTE:
Background Initialization (BGI) first initializes part of the RAID array space for data write
operations, and initializes the rest of the RAID array space in the background.
Full Ground Initialization (FGI) initializes the entire RAID array space. Data write operations
can be performed only when the initialization is complete.
3. On the screen as shown in Figure 140, select YES and press Enter.
Figure 140 Confirming the operation
Erasing drives
CAUTION:
To avoid drive failure, do not perform other operations when erasing a physical drive.
This task allows you to erase physical and logical drives.
Erasing a physical drive
1. On the PD Mgmt screen as shown in Figure 141, select the target drive and press F2.