EasyManuals Logo

H3C UniServer R4900 G3 User Manual

H3C UniServer R4900 G3
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #236 background imageLoading...
Page #236 background image
77
Figure 139 Selecting Initialization > Start FGI
NOTE:
Background Initialization (BGI) first initializes part of the RAID array space for data write
operations, and initializes the rest of the RAID array space in the background.
Full Ground Initialization (FGI) initializes the entire RAID array space. Data write operations
can be performed only when the initialization is complete.
3. On the screen as shown in Figure 140, select YES and press Enter.
Figure 140 Confirming the operation
Erasing drives
CAUTION:
To avoid drive failure, do not perform other operations when erasing a physical drive.
This task allows you to erase physical and logical drives.
Erasing a physical drive
1. On the PD Mgmt screen as shown in Figure 141, select the target drive and press F2.

Other manuals for H3C UniServer R4900 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C UniServer R4900 G3 and is the answer not in the manual?

H3C UniServer R4900 G3 Specifications

General IconGeneral
BrandH3C
ModelUniServer R4900 G3
CategoryServer
LanguageEnglish

Related product manuals