5
Figure 5 Manage Arrays screen
 If the operating system is installed on a physical drive, select Select Boot Device and
press Enter to open the screen as shown in Figure 6. The first drive in the Selected Drives
area on the right is the first boot option.
Figure 6 Select Boot Device
Replacing a storage controller
1. Replace the storage controller.
For more information, see the storage controller replacement procedure in the user guide for
the server.
2. Configure the storage controller. Make sure the replaced and the newly installed storage
controller operate in the same mode and have the same firmware version.
3. Configure the first boot option. Make sure the first boot option remains unchanged after the
storage controller replacement.