Hach ORBISPHERE 6110 - User Manual

Hach ORBISPHERE 6110
372 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DOC024.98.93009
ORBISPHERE Model
6110 Package Analyzer V3
04/2015, Edition 5
Basic User Manual
Allgemeines Benutzerhandbuch
Manuale dell'utente di base
Manuel d'utilisation de base
Manual básico del usuario
Manual Básico do Usuário
基本用户手册
基本取扱説明書
Základní uživatelská příručka
Basisgebruikershandleiding
Podstawowa instrukcja obsługi
Основно ръководство за потребителя
Alapvető felhasználói kézikönyv
manual fundamental de utilizare
Temel Kullanıcı Kılavuzu

Questions and Answers

  • A
    Austin LarsonSep 8, 2025
    What to do if Hach Measuring Instruments displays W1: Unstable reference pressure?
    • J
      john18Sep 8, 2025
      If the Hach Measuring Instruments displays warning W1, it means there is unstable reference pressure. This is because the variation of reference pressure is too high, so check the pressure stability of the input reference gas.
  • M
    Madison PatrickSep 7, 2025
    What to do if the bottle goes up with the piercing head in Hach ORBISPHERE 6110 Measuring Instruments?
    • S
      simpsonrobertSep 7, 2025
      If the bottle goes up with the piercing head, you can: * Stop the analysis by pressing the emergency STOP button, disconnect the instrument from the power supply, remove the bottle, check that the piercing spike is in place and not unscrewed, release the emergency STOP button by turning it clockwise, and restart the instrument. * Open the front door to stop the process, remove the bottle, check that the piercing spike is in place and is not unscrewed, close the front door, and press the Abort button on the screen.
  • S
    Shelia SchwartzAug 22, 2025
    What to do if Hach Measuring Instruments displays E4000: Calibration fails?
    • C
      Christopher BriggsAug 22, 2025
      If the Hach Measuring Instruments displays error E4000, it means that calibration fails because a leak during the headspace determination prevents a correct measurement. This can happen due to a bad piercing position, so pierce the package in a different position and change the Goretex filter.
  • G
    gonzalezmichaelSep 4, 2025
    What to do if Hach Measuring Instruments displays E200: Motor error - High limit?
    • J
      Joanna WashingtonSep 4, 2025
      If the Hach Measuring Instruments displays error E200, it indicates a motor error - High limit. This means that the motor is above the reference position, so go to the maintenance menu and initialize it.
  • H
    harrelldouglasSep 3, 2025
    What to do if Hach Measuring Instruments displays E40: Check gas supply, current pressure: nn?
    • B
      Brandon LesterSep 3, 2025
      If the Hach Measuring Instruments displays error E40, you should check the gas supply. This error indicates that before filling the reference volume, the pressure is lower than 1.5 bar, so check the purge gas pressure.
  • C
    Christopher KramerSep 2, 2025
    What to do if Hach Measuring Instruments displays W4: Measurement timeout?
    • Z
      zhallSep 2, 2025
      If the Hach Measuring Instruments displays warning W4, it means there was a measurement timeout and the accuracy of dissolved O2 is not guaranteed. This can be due to: * The measurement pressure is lower than 3.5 bar: Check the black seal on the piercing unit, the purge gas pressure, the forcing gas pressure and the Goretex filter. * Gas path not airtight: Check the airtightness of the gas path between the piercing unit and the measurement chamber.
  • J
    Jessica StephensAug 31, 2025
    What to do if Hach ORBISPHERE 6110 Measuring Instruments displays E800: Measurement stopped. The needle pressure is too low?
    • R
      rosswilliamsAug 31, 2025
      If the Hach Measuring Instruments displays error E800, it indicates that the measurement stopped because the needle pressure is too low. This is probably caused by air leaking from the piercing position, so pierce the package in a different position.
  • F
    fredericktaylorAug 30, 2025
    What to do if Hach Measuring Instruments displays E10: Foam has been detected in the gas path?
    • A
      Alec WilliamsAug 30, 2025
      If the Hach Measuring Instruments displays error E10, it means that foam has been detected in the gas path, and the measurement process is canceled. This can be due to several reasons: * There is a problem with the antifoam injection: Try another measurement. * Incorrect tilt of the sonotrode: Check the tilt of the sonotrode. * There is no more antifoam: Check the antifoam level and refill if necessary. Prime the antifoam pump. * The pressure in the package is greater than the purge gas pressure: Increase the purge gas pressure.
  • C
    Courtney JohnsonAug 29, 2025
    What to do if Hach ORBISPHERE 6110 Measuring Instruments displays E20: Not enough pressure in the system?
    • C
      Cynthia HoustonAug 29, 2025
      If the Hach Measuring Instruments displays error E20, it means there is not enough pressure in the system, so the measurement process is canceled. This can be due to a problem of flow regulation during the measurement, so check the purge gas pressure and change the Goretex filter. It can also happen if the gas path is partially or totally blocked, in this case control the antifoam injection.
  • C
    Christopher MillerAug 27, 2025
    What to do if Hach Measuring Instruments displays E4: The front door has been opened?
    • J
      Jesus PerezAug 27, 2025
      If the Hach Measuring Instruments displays error E4, it means the front door has been opened, stopping the measurement process. This can occur if the front door was opened before the measurement process completed, in which case you should close the front door. Alternatively, the front door might not be closed properly, so check the front door mechanism.

Summary

Specifications

General and Safety Information

General Information

Provides general notes on manufacturer liability and manual updates.

Safety Information and Hazard Warnings

Covers hazard symbols, warnings, and precautions for safe operation.

Installation and Initial Setup

Pre-installation Checks

Steps for preparing calibration standards, gas supplies, and sensor kits.

Physical Installation Process

Instructions for connecting the instrument to power and initial startup.

Post-installation Procedures

Covers language setup, security configuration, and initial sensor calibration.

User Interface and Operation

Instrument Power and Auto Check

How to switch the instrument on/off and the auto-check startup sequence.

Data Entry and User Identification

Using the virtual keyboard and logging in as an authorized user.

Instrument Options and Status Indicators

Overview of available instrument options and status indicators.

Configuration and Parameters

Units and Resolutions

Setting display units and resolution for measured parameters.

Package Parameters and Management

Defining parameters for package types, dimensions, and alarms.

Formula Management and Measurement Output

Creating formulas and defining measurement result display settings.

Security and Communication

Security and User Management

Enabling access rights, auto logoff, and managing user accounts.

Communication and Data Export

Configuring USB and Ethernet for data download and network connectivity.

Calibration Procedures

Calibration Schedule and Sensor Calibration

Recommended calibration intervals and steps for key sensors.

CO2, Oxygen, Flow, and Pressure Calibration

Detailed calibration steps for CO2, Oxygen, Flow, and Pressure sensors.

Measurement Process and Analysis

Starting a Measurement Analysis

Instructions for preparing and starting a package measurement.

Package Positioning for Measurement

Guidance on positioning bottles and cans for accurate piercing and measurement.

Reviewing Measurement Data

Viewing measurement results, comments, and historical data.

Maintenance and System Verification

Maintenance Schedule and Procedures

Daily, weekly, and periodic maintenance tasks for instrument upkeep.

Maintenance Wizards and Antifoam Preparation

Using guided wizards for maintenance and preparing antifoam.

Actuator Verification Checks

Checking manual displacement, antifoam system, ultrasound, and lasers.

Troubleshooting Guide

Error Messages and Solutions

Lists error messages, their probable causes, and recommended solutions.

Warning Messages and Causes

Details warning messages, probable causes, and suggested actions.

Measurement Problem Explanations

Explains common measurement issues and their underlying causes.

Hach ORBISPHERE 6110 Specifications

General IconGeneral
Measurement ParametersDissolved Oxygen, Ozone, Hydrogen Peroxide
Measurement Range (Ozone)0-20 mg/L
Response Time<60 seconds
Power Supply24 V DC
Communication InterfaceModbus
Applicationpharmaceutical