33
Operation
(6) The mode of indoor units can be inquired /changed by the
advanced setting function after the wired controller is powered
on, Only valid for part of models.
(7) Set as follows (Only valid for part of models):
Press Set key and Up key for 5s to enter the advanced setting
state, with the function A in temp. display area displayed
statically. Press Fan key to switch to function B. The function
code 01 displayed in the clock display area will ash. The 
specic information in the timing display area is statically 
displayed, it can be changed in the range of 00-03 by Up/
Down key. At this time press Set key to conrm, and the 
function code 01 in clock display area stays static, the specic 
information in the timing display area ashes, meaning it can 
be changed currently. Press Up/Down key to change the
content and Set key to conrm.
(8) If the mode is changed from more to less, the current mode
will not be in the mode of the present circulation. It will be the
fan mode after turn on.