45
Operation
(1) Powered off in cooling mode, keep pressing “ON/OFF” key
for 10 seconds, it will enter into the forced cooling function,
and the cooling mode icon will be displayed on the interface.
“LL” is ashing in the temp. area at the same time. Press “ON/
OFF” key to power off and exit forced cooling.
(2) Powered off in heating mode, keep pressing “ON/OFF” key
for 10 seconds, it will enter into the forced heating function,
and the heating mode icon will be displayed on the interface,
“HH” is ashing in the temp. area at the same time. Press “ON/
OFF” key to power off and exit forced heating.
(3) All the keys are invalid except “ON/OFF” key under forced 
cooling/heating mode, which can be cancelled by powering off
manually or receiving “trial operation” nished order from the 
communication. The former one can operate power off directly
while the later one will make the controller do by following the
order.
Forced Cooling/ Heating