8
8. CALIBRATION CHART
Example: To calibrate the 900M-T-LB tip at a room temperature of 22°C (70°F), adjust the CAL
potentiometer until the digital display reads 20 (66).
Room temperature:........... 22
°C (70°F)
Compensation value:........ -2°C (-4°F)
Digital display: .................. 20
°C (66°F)
900S
Tip No.
900S-T-1.2D
900S-T-1.6D
900S-T-2C
900S-T-1C
900S-T-B
900S-T-I
Compensation value
0
0
0
0
0
0
907
Tip No.
900M-T-0.8D
900M-T-1.2D
900M-T-1.6D
900M-T-2.4D
900M-T-3.2D
900M-T-1.2LD
900M-T-SB
900M-T-B
900M-T-LB
900M-0.5C
900M-0.8C
900M-T-1C
900M-T-1CF*
900M-T-1.5CF*
900M-T-2C
900M-T-2CF*
900M-T-3C
900M-T-3CF*
900M-T-4C
900M-T-4CF*
900M-T-K
900M-T-R
900M-T-RT
900M-T-SI
900M-T-I
900M-T-H
900M-T-1.8H
900M-T-S4
Compensation value
0
+2°C (+4°F)
0
0
0
0
0
0
-2°C (-4°F)
0
-2°C (-4°F)
0
0
0
0
0
0
0
0
0
+7°C (+12°F)
0
0
0
-2°C (-4°F)
-5°C (-9°F)
-2°C (-4°F)
+4°C (+7°F)
908
Tip No.
900L-T-B
900L-T-2B
900L-T-2.4D
900L-T-3.2D
900L-T-2C
900L-T-2CF*
900L-T-3C
900L-T-3CF*
900L-T-4C
900L-T-4CF*
900L-T-5C
900L-T-5CF*
900L-T-I
900L-T-K
Compensation value
0
0
0
0
-5°C (-9°F)
-5°C (-9°F)
0
0
0
0
0
0
-5°C (-9°F)
+5°C (+9°F)