15
Save Waveform
Press button to enter, and select Save to enter store waveform menu. The
waveform can be saved to the oscilloscope inside, also can be recalled to view.
The Save Menu Table
Setting
Description
1,2,3,4,5,6
Select the internal storage position.
Save waveform data.
Recall the waveform.
To save the waveform, follow these steps:
1. Press F1 to select the storage position of the waveform.
2. Press F2 to save the waveform data to the specified position.
3. Press F3, recall the saved waveform. The waveform can be enlarged or reduced in
the Channel or Time menu by using the direction keys.
Attention:
1. Waveform storage can not only save the waveform of the current channel, but also
save the current state settings at the same time.
2. Users can permanently store 6 waveforms in the oscilloscope memory and rewrite them
at any time.
Reference Waveform
The REF channel is used to display the reference waveform, which can compare the
actual waveforms with the reference waveforms so as to find out the differences.
Press button to enter, and select Ref to enter reference Waveform menu.
REF Menu Table
Setting
Description
Ref-A
Ref-B
The REF waveform is saved to the oscilloscope
Ref-A or Ref-B.
On
Off
Open the REF waveform.
Close the REF waveform.
CH1
CH2
Select CH1 to save as a REF waveform.
Select CH2 to save as a REF waveform
Save the REF waveform.
To save the reference waveform, follow these steps:
1. Press F1 to select the position of the reference waveform.
2. Press F2 to open the REF channel.
3. Press F3 to select the source to CH1 (or CH2), and only select the open channel.