Hantek2D82 Automotive Diagnostic Oscilloscope
User Manual
V1.4
Question and Answer IconNeed help?

Do you have a question about the Hantek Hantek2D82Auto and is the answer not in the manual?

Hantek Hantek2D82Auto Specifications

General IconGeneral
Bandwidth80 MHz
Channels2
Vertical Resolution8 bits
Trigger ModesEdge, Pulse, Video, Slope, Alternative
MultimeterYes
Vertical Sensitivity2 mV/div to 10 V/div
Time Base Range5 ns/div to 1000 s/div
Display7 inch TFT LCD
DMM FunctionsResistance, Capacitance, Diode, Continuity
Power Supply100V-240V AC, 50/60Hz
InterfacesUSB Host, USB Device, LAN
Input Impedance1 MΩ ± 2%
Supported InterfacesUSB

Summary

General Safety Summary

Safety Precautions

Essential safety guidelines to prevent injury and product damage, covering maintenance, power, grounding, and operation.

Safety Terms and Symbols

Getting Started

Initial Setup Procedures

Covers essential initial steps including inspection, safety keyhole use, bracket adjustment, front panel, user interface, functional check, and probe check.

General Inspection

Inspection Steps

Detailed checks for shipping container, accessories, and the instrument itself upon receipt.

Front Panel Overview

User Interface and Functional Check

Power and Waveform Observation

Steps for powering the device on/off, checking battery status, and performing a basic waveform observation.

Probe Check and Compensation

Probe Safety Guidelines

Safety warnings to prevent electric shock while handling and connecting probes.

Manual Probe Compensation Procedure

Detailed steps to manually adjust probe compensation for accurate measurements.

Probe Attenuation Settings

Menu and Control Keys

Connectors and Auto Set Function

Default Settings and Auto Function Details

Horizontal System Settings

Vertical System Settings

Trigger System Configuration

Trigger Source, Slope, and Mode

Configuring trigger source (CH1/CH2), slope (rising/falling), and trigger modes (Auto/Normal/Single).

Force Trigger and Level Adjustment

Using Force Trigger for acquisition and adjusting the trigger level for stable waveform display.

Waveform Saving and Reference

Measurement Functions

Cursor Measurement Setup

Instructions for enabling and using cursors to measure time and voltage parameters of signals.

Automatic Measurement and Utility Settings

Calibration and Shutdown Settings

Self Calibration Procedure

Steps for running the self-calibration routine to optimize measurement accuracy.

DMM Interface and Measurement

DMM Interface Overview

Description of the digital multimeter interface and its measurement types.

DC/AC Voltage Measurement

Procedure for measuring DC and AC voltage using the DMM function.

DMM Measurement Procedures

Current, Resistance, and Capacitance Measurement

Steps for measuring DC/AC current, resistance, and capacitance using the DMM.

Diode Measurement

Procedure for testing diodes using the multimeter function.

DMM Buzzer, Hold, and Notes

Buzzer and Data Hold Functions

Using the buzzer for continuity checks and the data hold function to freeze readings.

Waveform Generator

Generator Parameter Settings and Sine Wave Output

Charging and Battery Management

Troubleshooting Common Issues

Power-On and Display Problems

Solutions for issues like the oscilloscope not starting up or no waveforms displayed.

Waveform Distortion and Triggering Issues

Guidance for resolving distorted waveforms or continuous rolling without triggering.

General Care and Cleaning