AMPLIFIER SECTION BIAS ADJUSTMENT
Measurement condition
.No input signal or volume position is minimum.
Standard value
.Ideal current = 48mA (± 5%)
.Ideal DC Voltage = 25.92mV  (± 5%) 
CUP11911Y (MAIN PCB)
DC VOLTMETER  ; Connect to   
 CN66(SL),CN61(CEN),CN64(SR),CN63(FL),CN65(SBL/SL(AVR132,144,145)),CN62(FR),CN67(SBR)
NO.
1
2
3
Surround Left
Surround Right
4
5
Channel
Front Left
Front Right
Center
Adjust for Adjustment
25.92mV  (± 5%) 
CN65
CN64
25.92mV  (± 5%) 
25.92mV  (± 5%) 
25.92mV  (± 5%) 
25.92mV  (± 5%) 
CN63
CN62
CN61
CN66
CN67
6 Surround Back Left 25.92mV  (± 5%) 
25.92mV  (± 5%) Surround Back Right7