SL600 PINNACLE STAIR LIFT: Install Manual
30SEP2020 | P/N: 76015 REV F
22
TROUBLESHOOTING
PINNACLE STAIR LIFT: SECTION 6
SECTION 6
TROUBLESHOOTING
SAFETY SENSORS
If the LED indicator light is not green, check the
safety sensors.
• Seat swivel sensor: Seat should be in the locked
position.
• Footrest lower sensor: Check by pushing in on
the safety pan on the footrest.
• Upper foot pan safety sensor: Check by pushing
on the safety pan on the footrest.
• Front foot pan safety sensor: Check by pushing
on the safety pan on the footrest.
• Uphill safety sensor: Ensure that nothing is
blocking upward passage.
• Downhill safety sensor: Ensure nothing is
blocking the downward passage.
If the LED indicator light is still not green after
testing the sensors, turn the unit off and re-check all
the wire plugs. Turn the unit on again and re-check
the LED indicator light cycle. When the LED indicator
light remains green, the lift is ready to operate.
See Figure 6-1.
Figure 6-1
MAJOR FAULTS
Number of Beeps
Runaway 1
No Power 2
Conflicting switches FOOTREST UP and FOOTREST DOWN 3
Conflicting switches OBSTRUCTION UP and OBSTRUCTION DOWN 4
Conflicting switches FOOTREST DOWN and OBSTRUCTION UP 5
Conflicting switches FOOTREST UP and OBSTRUCTION DOWN 6
Conflicting switches STOP UP and STOP DOWN switches both detected 7
Conflicting switches STOP UP and STOP DOWN switches both NOT detected 8