76 1018854 12/2015 V01
Risk of death by electric voltages. Work in the area of live parts is extremely dangerous.
Work on the electrical system may only be performed by qualified electricians. The use of a power tool is absolutely
necessary.
Observing the five safety rules:
• Disconnect mains
• Prevent reconnection
• Test for absence of harmful voltages
• Ground and short circuit
• Cover or close o nearby live parts
The measures taken above must only be withdrawn when the work has been completed and the device is fully assembled.
Improper handling can cause damage to persons and property. The respective national, local and factory specific regulations
must be adhered to.
Burns from hot surfaces with temperatures of over 100° C
Let the motors cool down before starting work. Cooling times of up to 140 minutes may be necessary.
Wear protective gloves.
Do not work on hot surfaces!
Persons and property during maintenance and operation
Never perform maintenance work on running machinery. Secure the system during maintenance against re-starting and
unauthorised operation.
Cleaning
Excessive dirt, dust or chips may adversely aect the operation of the device and can, in extreme cases, lead to failure. At
regular intervals you should therefore, clean the device to ensure a sucient dissipation of the surface heat. Insucient
heat emissions can have undesirable consequences. The lifetime of the device is reduced if temperature overloads occures.
Overtemperature can lead to the shutdown of the device.
DANGER
ATTENTION
WARNING