ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation 5 Remote Control
Version 2.11, August 2011
5-28 Harris Corporation
Intraplex Products
Change Common Module Setup Parameters
You can change the CM-5RB setup by issuing SET commands with the appropriate parameter
names and values. Table 5-8 lists the CM-5RB setup parameters you can change remotely. For
example, to set line code to AMI in an ACS-163 terminal multiplexer with an address of 11, issue
this command:
11:TERM:SET:CODE=AMI;
Table 5-8. Parameter Names and Values for CM-5RB SET Commands
Parameter Function Values Sets Parameter To
FRAMING T1 framing
format
ESF Extended superframe
SF Superframe Also known as “D4”
CODE T1 line code B8ZS Bipolar with 8-zero substitution
AMI Alternate mark inversion
PTIME Primary timing
mode
INT Internal (terminal multiplexers only)
EXT External (terminal multiplexers only)
LOOP Loop (terminal multiplexers only)
THRU Through (drop and insert multiplexers only)
LINE-LB T1 line loopback ON Activate the line loopback.
OFF Deactivate the line loopback.
PAYLD-LB T1 payload
loopback
ON Activate the payload loopback.
OFF Deactivate the payload loopback.
EQPT-LB T1 equipment
loopback
ON Activate the equipment loopback.
OFF Deactivate the equipment loopback.
WARNING! Do not activate the payload and equipment loopbacks simultaneously. When the
control circuit is carried as a channel on the T1 circuit, never command the far end multiplexer
to initiate an equipment loopback. You cannot turn this loopback off by remote control.
CH-ALM Selects alarms
from the
channel card
SCB addresses
that can
generate a shelf
alarm
ALL All SCB addresses reporting an alarm condition are logically
sent to the shelf alarm.
NONE No SCB addresses reporting an alarm condition are sent to the
shelf alarm.
1 to 36 The SCB address (1-36) are sent to the shelf alarm. Any
subsequent SCB address number are also sent to the shelf
alarm.
RESET Resets the CM-
5RB module to
factory defaults
DFLT These are the default settings:
FRAMING = ESF
CODE = B8ZS
PTIME = INT (on terminal multiplexers)
PTIME = THRU (on drop and insert multiplexers)
LINE-LB = OFF
PAYLD-LB = OFF
EQPT-LB = OFF
CH-ALM = ALL
All other CM-5RB parameters are not affected by a RESET
command.
Table 5-9 shows the ISiCL “SET” parameters that support CM-5RB combined line and module
redundancy.