5 Remote Control ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Harris Corporation 5-35
Intraplex Products
Figure 5-16. Turning Modules On and Off with Remote Control
First, type the command:
::UNLOCK:GREEN;
The system acknowledges the command with this response:
* OK;
The remote port is now unlocked. If you then type the command:
:C12:CONFIG?:;
the system response appears in Table 5-15.
Table 5-15. Explanation of CONFIG? Response for Example 1
Response Meaning
* OK
A valid query was received.
CHANNEL CARD 12, TYPE 202
Module SCB address 12 is a PT-153 module.
UNDER REMOTE CONTROL
Set to remote control.
SRVC = ON
Service is on (module is active).
P01 = 15 (B00001111)
First left channel time slot is set to 15.
P02 = 16 (B00010000)
Second left channel time slot is set to 16.
P03 = 17 (B00010001)
First right channel time slot is set to 17.
P04 = 18 (B00010010)
Second right channel time slot is set to 18.
P05 = 1 (B00000001)
Set to 15kHz bandwidth.
P06 = 1 (B00000001)
Both left and right channels are active.
P07 = 1 (B00000001)
Left channel is set to 15-bit coding.
P08 = 1 (B00000001)
Right channel is set to 15-bit coding.
P09 = 0 (B00000000)
Set for terminal (or DI-A) operation.
P10 = 0 (B00000000);
The scrambler is off.