Harris Corporation A-1
Intraplex Products
Appendix A – ISiCL CM-5RTD Delay Configuration
The configuration and status monitoring of the optional delay feature are controlled by ISiCL through
the remote control interface. The delay feature parameters are controlled using P (parameter) codes;
the status is retrieved using S (status) codes. These features correspond to the manual switch settings
discussed in the TDLY section of Table 4-1 and the procedures in Section 4.7.1.2 - CM-5RTD Sub-
address. For example, to set smooth (hitless) buffer depth change on a CM-5RTD module whose delay
feature has an address of 2, and with a multiplexer address of 11, issue this command:
11:C2:SET:P02=B00000000;
You can turn service on or off for the delay feature by sending
SRVC = ON or SRVC = OFF
in the ISiCL parameter field with a SET command.
A.1 Delay P Codes
P codes allow you to set parameters on the CM-5RTD delay feature when used in the parameter field
of an ISiCL SET command. There are four P codes for the CM-5RTD delay feature:
P01
P02
P03
P04
Each is a number from 0 to 255, also represented as an eight-digit binary number in parentheses.
Table A-1 describes the meanings of the P codes. P codes also appear in the response to a CONFIG?
query, showing the current parameter settings on the card:
* OK
CHANNEL CARD 1, TYPE 12
UNDER REMOTE CONTROL
SRVC = ON
P01 = 0 (B00000000)
P02 = 0 (B00000000)
P03 = 3 (B00000011)
P04 = 135 (B10000111);
When using binary numbers in the parameter field of a SET command, they must be preceded by the
letter “B.” For example:
<multiplexer address>:<card address>:SET:P02 = B00000001;