Intraplex
®
ACS-160 & STL-160 Series T1 Multiplexer
Installation & Operation Manual
ACS-163 Terminal Access Server (3RU)
ACS-165 Drop & Insert Access Server (3RU)
ACS-166 Dual Terminal Access Server (3RU)
ACS-167 Terminal Access Server (1RU)
ACS-168 Drop & Insert Access Server (1RU)
ACS-169 Dual Terminal Access Server (1RU)
STL-163 Studio-to-Transmitter Link (3RU)
STL-165 Studio-to-Transmitter Link (3RU)
STL-166 Studio-to-Transmitter Link (3RU)
CM-5RB Common Module
CM-5R-TD Time Delay Common Module
Version 2.11
TOTAL CONTENT DELIVERY SOLUTIONS | Managing content. Delivering results.

Table of Contents

Questions and Answers

  • M
    Michael JohnsonJul 31, 2025
    What to do if the CPU failed on my Harris Intraplex STL-160 Multiplexer?
    • J
      James Simpson DDSJul 31, 2025
      If the Harris Multiplexer CPU has failed, replace the module with a spare.
  • L
    Louis WardAug 4, 2025
    What to do if there is a loss of receive signal on my Harris Intraplex STL-160 Multiplexer?
    • N
      Natalie Wagner MDAug 4, 2025
      If the Harris Multiplexer is experiencing a loss of receive signal, contact your T1 carrier to verify that the T1 circuit is operating.
  • S
    Sarah UnderwoodAug 9, 2025
    What to do if the signal is present but out-of-frame on my Harris Intraplex STL-160 Multiplexer?
    • H
      heathermoralesAug 9, 2025
      If the Harris Multiplexer is showing a signal present but out-of-frame, contact your T1 carrier to find out what kind of frame format is in use on the T1 circuit and ensure that this format is set correctly on the multiplexers at both ends of the T1 circuit.
  • W
    walkermarkAug 15, 2025
    What to do if my Harris Intraplex STL-160 Multiplexer is receiving a yellow alarm?
    • A
      adam43Aug 15, 2025
      If the Harris Multiplexer is showing a yellow alarm, contact your T1 carrier to resolve the problem.
  • J
    jacksondebraAug 20, 2025
    What to do if my Harris Multiplexer is receiving alarm indication signal?
    • T
      Teresa SmithAug 20, 2025
      If the Harris Multiplexer is showing an alarm indication signal, contact your T1 carrier to resolve the problem.
  • J
    Jennifer RamosAug 26, 2025
    How to fix no transmit output on Harris Multiplexer?
    • H
      Hannah LeeAug 26, 2025
      If the Harris Multiplexer has no transmit output, replace it with a spare.

Summary

Section 2 - Functional Design

2.1 Component Functionality

Explains the functions of the ACS-160/STL-160 multiplexer components.

2.1.3 CM-5 RB Common Modules

Details the operational functions of the CM-5RB common module.

Section 3 - Installation & Wiring

3.6 Wiring & Power

Provides guidelines for wiring power and connectors.

Section 4 - Setup & Configuration

4.2 CM-5 RB Basic Configuration Group Menu

Describes the CM-5RB module's basic configuration menu structure.

Section 5 - Remote Control Operation

5.2 User Interfaces

Describes the methods to access the multiplexer system remotely.

5.2.3 Intraplex Simple Command Language (ISiCL)

Details how to use ISiCL for configuring and operating the multiplexer.

Section 6 - Testing & Troubleshooting

6.3 Diagnostic Functions

Introduces internal functions for testing and troubleshooting.

6.6 Troubleshooting

Presents a general approach to troubleshooting ACS-160 systems.

Section 7 - Specifications

Harris Intraplex STL-160 Series Specifications

General IconGeneral
TypeMultiplexer
Audio Channels16
Audio FormatAES3, Analog
Transmission MediumCopper, Fiber
Power Supply100-240 VAC, 50/60 Hz
Channels16
InterfacesEthernet
GainAdjustable
Operating Temperature0°C to 50°C