EasyManua.ls Logo

Harris Intraplex STL-160 Series - Delay S Codes; Table A-1. Delay Feature P Codes

Harris Intraplex STL-160 Series
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACS-160 Series & STL-160 Series T1 Multiplexer A-ISiCL CM-5RTD Delay Configuration
Version 2.1, April 2011
A-2 Harris Corporation
Intraplex Products
Table A-1. Delay Feature P Codes
P
Code
Binary Digits
Value Description 1 2 3 4 5 6 7 8
P01 B 0 0 0 0 0 0 0
0 0 Sets normal polarity for the RS-422 control input.
1 Sets inverted polarity for the RS-422 control
input (can correct for reversed wires at the RS-
422 interface).
B 0
0
0
0
0
0
0 0
Not used These digits must be set to zero.
P02 B 0 0 0 0 0 0 0 0
0 or 1 Most significant bit of the delay setting (Section
A.4Delay Setting with RS-232 Remote Port).
B 0 0
0
0
0
0
0
0 Not used These digits must be set to zero.
B 0
0 0 0 0 0 0 0 0 Step (non-hitless) change in depth.
1 Smooth (hitless) change in depth.
P03 B 0
0
0
0
0
0
0
0
0 or 1 Second through ninth most significant bits of the
delay setting (Section A.4Delay Setting with
RS-232 Remote Port).
P04 B 0
0
0
0
0
0
0
0
0 or 1 Eight least significant bits of the delay setting
(Section A.4Delay Setting with RS-232 Remote
Port).
A.2 Delay S Codes
There are four S codes for the delay feature of a CM-5RTD module. Table A-2 defines these S codes
which appear in response to a STATUS? query. Like the P codes, the S codes are displayed in both
decimal and binary form:
* OK
CHANNEL CARD 1, TYPE 12
S01 = 0 (B00000000)
S02 = 0 (B00000000)
S03 = 3 (B00000011)
S04 = 135 (B10000111);