EasyManua.ls Logo

Harris Intraplex STL-160 Series - Delay Setting with RS-422 Control Port

Harris Intraplex STL-160 Series
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-ISiCL CM-5RTD Delay Configuration ACS-160 Series & STL-160 Series T1 Multiplexer
Version 2.1, April 2011
Harris Corporation A-5
Intraplex Products
:C2:SET:P2=100000000; Select smooth change
:C2:SET:P4=B10011110; Set low-order 8 bits for 29.95 milliseconds (no change in high-order 8
bits is required)
A.5 Delay Setting with RS-422 Control Port
This method uses the RS-422 control “port” to change the delay value. The control port is part of the
physical external timing input connector. Table 2-10 shows the MA-215/MA-217B/MA-235-1/MA-235-2
timing in port pin assignments.
The control port is a receive-only RS-422/RS-485 serial port configured to accept an asynchronous
9600 bps data stream with these elements:
One start bit
Eight data bits
No parity
One stop bit
The control port recognizes four different information bytes. Each of these four bytes consists of two
identifying bits and six data bits (Figure A-2); the 24 data bits contained in these four bytes are
identical to the 24 bits in P02, P03, and P04 under ISiCL (Section A.1Delay P Codes). The least
significant (right-hand) bit is transmitted first. As when using P codes, it is best to send the most
significant bits first.
Figure A-2. RS-422 Control Port Information Bytes

Table of Contents

Related product manuals