1 Introduction ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Harris Corporation 1-3
Intraplex Products
The ACS-166 and ACS-169 product packages each provide two T1 terminal multiplexers in a single
shelf. The multiplexers share the same power supply and alarm reporting system but are otherwise
independent; there is no communication between the two T1 circuits.
Note: Unless otherwise specified, all references to the ACS-163 multiplexer also apply to the ACS-
167 multiplexer, all references to the ACS-165 multiplexer also apply to the ACS-168
multiplexer, and all references to the ACS-166 multiplexer also apply to the ACS-169
multiplexer.
Figure 1-1. ACS-163, ACS-165, and ACS-166 Multiplexers, Front View (with cover)
INTRAPLEX
STL HD
Figure 1-2. STL-163, STL-165, and STL-166 Multiplexers, Front View (with cover)
Figure 1-3. ACS-167, ACS-168, and ACS-169 Multiplexers, Front View (with cover)
1.4 Multiplexer Component Parts
1.4.1 Main Equipment Shelf
The main equipment shelf is 19" wide rack-mount, 5¼" high for a 3RU multiplexer or 1¾" high for a
1RU multiplexer. This equipment shelf has slots for
Plug-in common modules
Channel modules
Module adapters
Power supplies
Warning! All common modules, channel modules, and power supplies must be inserted so that the
white eject tab is at the bottom in a 3RU shelf and at the right in a 1RU shelf.