2 – Functional Description ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Harris Corporation 2-29
Intraplex Products
Figure 2-25. ACS-165 Drop and Insert System
A three-location system can provide circuits between these locations
● 1 and 2
● 2 and 3
● 1 and 3
The only limiting factor is the 24-time slot capacity of the T1 circuit between any two adjacent
locations. Drop and insert systems are not limited to a single drop and insert multiplexer. In fact, you
can use them to link as many as one hundred locations.