EasyManua.ls Logo

Harris Intraplex STL-160 Series - Section 5 - Remote Control Operation; 5.1 Physical Connections

Harris Intraplex STL-160 Series
178 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No header
Harris Corporation 5-1
Intraplex Products
Section 5 – Remote Control Operation
This section discusses multiplexer physical connections for remote control and various ways you can
remotely configure and operate an ACS-160 Series or STL-160 Series multiplexer. You can physically
connect your multiplexer in one of three ways:
A serial cable connection to the shelf via the remote port (Section 5.1.1)
DS0 management communication (Section 5.1.2)
An SCM-IP module and an MA-440 module adapter connecting to an IP network (Section 5.1.3)
Likewise, you can use one of these interfaces to configure and operate the multiplexer:
IntraGuide Configuration and Management Software (all three connections Section 5.2.1)
SNMP via the SCM-IP module (third connectionSection 5.2.2)
Intraplex Simple Command Language (ISiCL first two connections Section 5.2.3)
5.1 Physical Connections
5.1.1 Remote Port
The ACS-160 Series and STL-160 Series multiplexers can be set up and monitored via the RS-232
remote port, which can be connected in any of these ways:
To a local PC (Figure 5-1)
In a daisy-chain manner with other Intraplex control modules (Figure 5-2)
To an SCM-IP module (Figure 5-3)
A terminal multiplexer has one remote port while a dual terminal or drop and insert multiplexer has
two remote ports. Remote ports are RS-232C compatible, asynchronous, serial interfaces which can
operate at baud rates from 110 bps to 57.6 kbps. Each CM-5RB common module has one remote port
connector. The remote port connector also includes an RS-485 interface which can be used to create a
daisy-chain connection to other Intraplex systems.
The remote port for each CM-5RB module is located on its associated module adapter. The MA-215,
MA-217B, and MA-235-2 module adapters have RJ-11 jacks for the remote port. The pin assignments
for this connector appear in Section 3.6.4 - Remote Port Wiring (Optional).
Figure 5-1. Direct Connection to Multiplexer
Note: You can also connect multiple CM-5RB modules in a daisy-chain configuration with the output
of a common module connected to the input of another common module, using special
Intraplex cables and adapters.

Table of Contents