ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation 3 – Installation & Wiring
Version 2.11, August 2011
3-18 Harris Corporation
Intraplex Products
Figure 3-17. Connection for AC Operation of 3RU System with External Signal Battery
Figure 3-18. Connection for AC Operation of 1RU System with External Signal Battery
* In place of a separate signal battery, you can use a 48V DC power source with a parallel
connection from -BAT A to the SIG BAT input and +BAT to GND.
3.6.5.1 Dual AC Feeds
All 3RU multiplexers can be equipped with an ACS-OPT1 option, providing separate AC power feeds for
each power supply. When the ACS-OPT1 option is in place, the rear panel looks like Figure 3-19. For
maximum redundancy, connect the two power cords to two different AC power sources.
Figure 3-19. 3RU Multiplexer Rear Panel with ACS-OPT1 Dual AC Power Feed Option