ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation 4 Setup & Configuration
Version 2.11, August 2011
4-6 Harris Corporation
Intraplex Products
Table 4-2. Primary CM-5RB Initial Display
Front Panel
Display Indicated Mode
TERM Terminal multiplexers
DI-A DI-A in a drop/insert multiplexer
DI-B DI-B in a drop/insert multiplexer
SPAR Spare
Note: These procedures include use of the GROUP and SET/NEXT switches. If you are not already
familiar with using these switches, please review Section 1.5 – CM-5RB User Interface before
proceeding.
4.2.1 Access Configuration Group
Use these steps to access the configuration group:
1. Press down repeatedly on the GROUP switch until the display reads TIME.
2. Release the switch. You are now in the Configuration Group.
Figure 4-1 shows the switch and indicator locations.
4.2.2 Display and Change Items in Basic Configuration Group
1. Press down repeatedly on the SET/NEXT switch until the display shows the menu you want to
change.
2. Note that some items are underscored, indicating an additional subgroup. Complete the next two
steps to enter and cycle through any subgroups.
3. Press up once on the SET/NEXT switch to display the first of the subgroup options.
4. Press down repeatedly on the SET/NEXT switch to cycle through other subgroup options.
5. Press up twice on the SET/NEXT switch. After the first press the green (top) light blinks, indicating
a change is about to be made. After the second press, it turns on continuously, indicating the
option you wanted to change is now enabled.
These areas of the manual give details on basic menu functions:
T1 operational functions: Section 4.4 – T1 Transmitter Timing (TIME Group) and Section 4.5 –
T1 Frame Format and Line Code (TSEL Group) describe the timing (TIME) and signal format/line
code (TSEL) groups, respectively. Section 4.6 Redundant CM-5RB (REDN Group) describes
redundant CM-5RB settings.
Diagnostic functions: Section 6 – “Testing and Troubleshooting” describes the loopback (LPBK)
and informational (BLNK, RVU1, and DIAG) groups.
Remote access setup functions: Section 5.1.1.2Configuration – Network Address (ADDR
Group) Setting and Section 5.1.1.3Configuration – Remote Port Parameters (SIO Group) Setting
describe the shelf address (ADDR) and remote port (SIO) groups respectively. Section 5.1.2
DS0 Management Communications describes internal DS0 management control settings (COMM).
4.3 CM-5RB Advanced Configuration Group Menu
In addition to the basic configuration features, the CM-5RB module also contains an Advanced
Configuration Group for controlling specialized functions that rarely need adjustment in most systems.