4 Setup & Configuration ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Harris Corporation 4-3
Intraplex Products
Table 4-1. CM-5RB Basic Configuration Group
Group Selections Description
TSEL TLBO Sets the line build-out range for the T1 port on the CM-5RB module. The
display shows the midpoint of the range (Section 4.5 T1 Frame Format and
Line Code (TSEL Group)).
RED = not selected, GREEN = selected
DSX
(default)
Sets build-out for DSX standard (0' to 133').
200’ Sets build-out for 133' to 266'.
333’ Sets build-out for 266' to 399'.
467’ Sets build-out for 399' to 533'.
595’ Sets build-out for 533' to 655'.
7dB Network build-out for -7.5 decibels.
15dB Network build-out for -15 decibels.
exit Exits TLBO and displays sub-menu.
CSU Channel Service Unit Sets the standard for the CM-5RB modules integrated
CSU (Section 4.5.1CSU Configuration).
RED = not selected, GREEN = selected
Off Disables the integrated CSU for operation with an external CSU.
ATT Sets the standard for the CM-5RB modules integrated CSU to AT&T TR54016
compliant.
ANSI
(default)
Sets the standard for the CM-5RB modules integrated CSU to ANSI T1.403
compliant.
exit Exits CSU and displays sub-menu.
SF Sets the framing format to Superframe.
RED = not selected, GREEN = selected
ESF (default) Sets the framing format to Extended Superframe.
RED = not selected, GREEN = selected
AMI Sets the line coding to alternate mark inversion.
RED = not selected, GREEN = selected
B8ZS (default) Sets the line coding to B8ZS.
RED = not selected, GREEN = selected
PDE Pulse density enforcement; for AMI mode to force a one after 15 consecutive
zeros (Section 4.5.2 – Framing and Line Code Configuration).
RED = not selected, GREEN = selected
TIME Source of multiplexer’s timing (Section 4.4 T1 Transmitter Timing (TIME
Group)).
RED = not selected, GREEN = selected
Loop Loop timing of T1 link – Only displays if the CM-5RB module is in TERM mode.
Int (default) Internal timing of T1 link – Only displays if the CM-5RB module is in TERM
mode.
Ext External timing of T1 link – Only displays if the CM-5RB module is in TERM
mode.
Thru Through timing of the T1 link – Only displays if the CM-5RB module is in DI-A
or DI-B mode.