ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation 7 Specifications
Version 2.11, August 2011
7-4 Harris Corporation
Intraplex Products
Power
Connector On the rear panel of the multiplexer
For AC: 3-prong jack
For DC: Terminal strip (3RU shelves)
Consumption 2.6 watts (3.6 watts w/module adapter) for each CM-5RB common module
(one in a terminal multiplexer, two in a dual terminal or drop/insert
multiplexer), plus channel module consumption
Power Supply
Modules for
Three-Rack Unit
(3RU) Shelf
PSY60AC
(standard)
PSY5024
PSY5048
PSY100AC
Nominal Input Voltages: 115 VAC or 230 VAC
Input Voltage Range: 90 to 264 VAC
Input Fuse: 2A (slow blow)
Output Power: 60 Watts
Nominal Input Voltage: -24 VDC
Input Voltage Range: -20 to -36 VDC
Input Fuse: 5A (slow blow)
Output Power: 50 Watts
Nominal Input Voltage: -48 VDC
Input Voltage Range: -40 to -72 VDC
Input Fuse: 5A (slow blow)
Output Power: 50 Watts
Nominal Input Voltages: 115 VAC or 230 VAC
Input Voltage Range: 90 to 264 VAC
Input Fuse: 2A (slow blow)
Output Power: 95 Watts
Power Supply
Modules for One-
Rack-Unit (1RU)
Shelf
Nominal Input Voltages: 115 VAC or 230 VAC
Input Voltage Range: 90 to 264 VAC
Input Fuse: 2A (slow blow)
Output Power: 30 Watts
Signaling
Battery Inputs
Signaling
Voltage: -60 VDC maximum
Fuse: 2A Slow-blow, external (required)