ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation 4 Setup & Configuration
Version 2.11, August 2011
4-10 Harris Corporation
Intraplex Products
Table 4-3. CM-5RB Advanced Configuration Group Menu (continued)
Function Group Description
TXYL Transmit yellow alarm function
RED = not selected, GREEN = selected
Off Yellow alarm is off (never active)
On Yellow alarm is on (always active)
Auto Automatically sends yellow alarm
ESF (Default) Automatically sends yellow alarm only in ESF
exit Exit TXYL and display TYPE
TYPE Multiplexer type. This function sets the basic multiplexer type
RED = not selected, GREEN = selected
VRM Sets unit to run as a variable-rate multiplexer
T1 (Default) Sets unit to run as an T1 multiplexer
exit Exit TYPE and display PRIM
PRIM Primary mode. This function sets the primary operating mode for the
CM-5RB module. When the common module is first plugged in, it
determines its mode based on the setting of the DIP switches on the
MA-215, MA-235-1, MA-235-2 or MA-217B module adapter. You can use
PRIM to override these switch settings.
RED = not selected, GREEN = selected
TERM Sets the mode to terminal
DI-A Sets the mode to DI-A (drop and insert multiplexer)
DI-B Sets the mode to DI-B (drop and insert multiplexer)
SPAR Sets the mode to spare (inactive)
exit Exit PRIM and display PLL
PLL Phase-locked loop filter. This function sets the bandwidth of the filter in
the phase-locked loop (PLL) used to derive the transmit timing from the
input T1. The PLL is used when the timing is set to loop, through, or
external.
RED = not selected, GREEN = selected
Auto (Default) Determines the width based on the timing in use: narrow for loop or
external timing, wide for through timing.
Narr Forces the setting to narrow
Wide Forces the setting to wide
exit Exit PLL and display EIB
CUST Customer application menu
RED = not selected, GREEN = selected
Std (Default) Standard alarm declaration criteria
KT Modified alarm criteria
STL Modified alarm criteria for use in studio-to-transmitter links (STLs)
FTI Modified line criteria