Hayward ProLogic - Troubleshooting: No Cell Power;Low Volts

Hayward ProLogic
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
No Cell Pwr.
/Low Volts
Is 24VAC
present?
YES
NO
Check 20A
fuse
Is fuse
damaged?
YES
Check Rectifier
wiring
1. No Cell Power/Low Volts
Verify 24VAC on
the transformer
output
Verify
transformer
input
Replace fuse
(GLX-F20A-
10PK)
NO
Is wiring
correct?
Replace main
board
(see pg. 17)
YES
NO
Correct
wiring
Is 120VAC available
on both
transformer
inputs?
NO
YES
Replace
Transformer
(GLX-XFMR)
120VAC present on
input power,
terminal block?
Test Main PCB
input power
NO
Resolve source
power issue
Replace main
board
(see pg. 17)
YES