Feature 07 – Optimum Start: Optimum start will delay the start up of the heating
system to the latest possible moment to avoid unnecessary heating and ensure the
building is warm at the programmed time. The thermostat uses the rate of change
information to calculate how long the heating needs to raise the building
temperature 1°C (with a rate of change of 20, the thermostat has calculated the
heating needs 20 minutes to raise the building temperature 1°C) and starts the
heating accordingly.
Feature 08 – Rate of Change: For information only.
Feature 09 – Program Mode: The following program modes are available;
5/2 Day Programming – 4 levels for the weekdays and 4 different levels for the weekend.
7 Day Programming – 4 levels for each day.
24 Hours – 4 levels over a 24-hour period.
Feature 10 – Thermostat Mode: Here you can set in which mode you would like the
thermostat to operate. The options are, manual (non-programmable), programmable,
or programmable with hot water time clock.