3.3  Feed  rate  release 
Input  PLC-Allocation 
TNC  151  B/TNC  155  B  TNC  151  Q/TNC  155  Q 
Multipoint  connector  Multipoint  connector 
PLC-Power  board 
“Feed  rate  release” 
El8  J 516 
J 515 
By  opening  the  input  “feed  rate  release”, 
the  speed  can  be  ramped  down  to  zero  at  (any time,  by  means  of  the 
“machine  acceleration”  which  is entered  as a machine  parameter  during  initial  dialogue  entry. 
If  the  input  “feed  rate  release”  has been  opened,  this  is indicated  in  the  status  display  by  the  letter  F  (inverted). 
3.4  M-,  S- and  ‘T-functions,  Strobe  signals  and  feedback  signal: 
“Auxiliary  function  completed” 
In/Output 
Coded  outputs 
M,  S and  T 
Bit  1 . . . 20 
2  . . . 2’ 
3  . . . 22 
Decade  1 
4 . . . 23 
5 . . . 20 
6 . . . 2’ 
7 . . . 22 
8 . . . 23 
Decade  2 
Decoded  outputs 
M  03  Spindle  cw 
M  04  Spindle  ccw 
M  05  Spindle  stop 
M  08  Coolant  ON 
M  09  Coolant  OFF 
Gating  signals 
S-Strobe 
M-Strobe 
T-Strobe 
Input:  “Auxiliary  function 
completed” 
PLC-Allocation 
A7 
A8 
A9 
Al0 
All 
Al2 
Al3 
Al4 
Al5 
Al6 
Al7 
Al8 
Al9 
A20 
A21 
A22 
El7 
TNC  151  B/TNC 
155  B 
Multipoint  connector 
J 212 
J 213 
J 
214 
J 
215 
J 
216 
J 
217 
J 
218 
J 
219 
J 
2llO 
J2ll-l 
J 
2112 
J 
3/l 
J 
312 
J 
313 
J 
314 
J 
315 
J 
5l7 
TNC  151  Q/TNC  155  Q 
Multipoint  connector 
PLC-Power  board 
- 
J 
II8 
J 
II9 
J 
Ill0 
J 
Ill1 
- 
J 
2/l 
J 
212 
J 
213 
J 
214 
-_ 
J 
2l5 
J 
216 
J 
217 
J 
218 
J 
219 
- 
J 
2110 
J 
2/l  1 
J3ll 
- 
J 
516 
- 
M-,  S- and  T-functions  are  provided  statically  via  the  same  relay  outputs  of  the  control.  To  differentiate 
whether  an  M-,  S- or  T-function  is at  the  output,  pulsed  strobe  signals  “M-Strobe”,  ‘S-Strobe”  and  “T-Strobe” 
are  used. 
Via  machine  parameter  MP  214  it  can  be determined  as to  whether  a brief  axis  standstill  occurs  with  a 
change  of  spindle  speed  during  a constant  positioning  procedure.