3.8  External  direction  buttons  and  external  feed  rate  potentiometer 
Inputs  PLC-Allocation  TNC  151  B / 
TNC  155  B 
Multipoint 
connector 
TNC  151  Q/ 
TNC  151  Q / 
TNC  155  Q 
TNC  155  Q 
Multiipoint 
Multipoint 
connector  connector 
PLC-Power  board  control 
X  +  direction 
x-  “ 
J6/5 
J4/3 
- 
J6/6 
J4/2 
- 
y+” 
J6/7  J5/12 
- 
y-  ‘I 
J6/8  J5/1  ‘I 
- 
z  +  ” 
El3 
z  -  ” 
El4 
IV  +  ” 
El5 
IV  -  “ 
El6 
J6/9  J5/10 
- 
J6/10 
J5/9 
- 
-- 
J6/11  J5/8 
- 
J6/12 
J5/7 
- 
ext.  Potentiometer  +  12  V 
- 
J3/6 
- 
J3/2 
l,  I, 
brush-contact  - 
J3/8 
- 
J3/3 
I,  I, 
ov 
- 
J3/9 
- 
J3/4 
By  applying  the  24  volt  control  voltage  via  an external  direction  button,  the  relevant  machine  axis  can  be 
traversed  in  the  modes:  MANUAL  OPERATION,  ELECTRONIC  HANDWHEEL  and 
PROGRAMMING  AND  EDITING.  The  max.  speed  for  each  axis  is programmed  separately  via  machine 
parameters  4  to  7. 
A  feed  rate  display  F  is provided  in  the  display  screen.  This  display  operates  in  acoordance  with  machine  para- 
meter  167  either  after  the  start  of  one  axis  via  display  or  with  the  same  max.  feed  rate  in  all  axes  prior  to  start. 
Machine  parameter  74  determines  whether  the  feed  rate  is output  in  2  % stages or  variable. 
Caution: 
With  F-display  prior  to  start,  the  control  sets the  smallest  programmed  speed  in  MP4  to  MP7  for  all  axes. 
With  a further  machine  parameter  MP66,  the  input  of  another  existing  external  feed  rate  potentiometer  can  be 
activated.  If  no  external  feed  rate  potentiometer  is used,  the  feed  rate  for  the  direction  buttons  can  be set via 
the  override  potentiometer.  The  rapid  traverse  button  is active  with  one  or  sever-al direction  buttons. 
If  the  external 
0 
START-button is pressed  while  one  or  more  direction  buttons  are  held  depressed,  the  traversing 
directions  are  memorised  depending  on  the  programming  of  machine  parameter  MP  68.  This  motion  can  be 
stopped  via  the  external 
0 
STOP 
-button. 
27