EasyManua.ls Logo

HEIDENHAIN TNC 151 Q - 2 Combined Technical Specifications

HEIDENHAIN TNC 151 Q
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HEIDENHAIN TNC lSl/TNC 155 with SPINDLE ORIENTATION option
.Spindle orientation is available as an option and necessitates an extension of TNC-hardware.
The NC-software for spindle orientation, i.e. for the fifth axis is contained in every TNC 151 B/TNC 155 B.
Installation hints for VDU-units
(Control versions TNC 151 permit the installation of the VDU-unit BE 111 (9 inch screen) or BE 211
(12 inch screen). TNC 155~versions require the VDU-unit BE 411 (12 inch graphic display screen).
When installing VDU-units, it should noted that these units are sensitive to magnetic fields. The hold and
geometry o-f the screen picture can be distorted by magnetic cross-talk.
In the case cof alternating current fields, these can cause periodical picture displacement or picture
distortion with the beat frequency from the picture and the mains frequency.
For this reason, permanent magnets, motors, transformers, magnetic switches and similar should not be
located in the immediate vicinity of the VDU. As an approximation, we recommend a minimum distance
of 0.5 m between the source of interference and the VDU-housing.
In order to maintain a substantial distance between the VDU and the control unit (TNC), we recommend
that the TNC only be mounted to the right or beneath the VDU.
2. Combined technical specifications for TNC 15l/TNC 155
All TNC 151/TNC 155 inputs and outputs may only be connected to electric circuits with protective low
voltage.
Mains power supply
‘Power consumption
Selectable 100/120/l 40/200/220/240 V + 10 %/ - 15 %, 48 . 62 Hz
If -the permissible mains voltage tolerances cannot be held, we recommend
a voltage regulator type “Voltkraft” which1 is available from Messrs. Conrad
Electronic. The regulator can also be purchased from the HEIDENHAIN
Service Department.
TRIG 151
ca. 60 W (with 9” visual display unit BE 1 ‘I 1 or with 12” visual display
unit BE 211)
TNC 155
Permissible resistance of
earthing lead
Protection algainst distruction
of electronics
Ambient temperature
Protection
Weight
Logic and operating unit ca. 45 W
12” visual display unit BE 411 ca. 40 W
Current consumption of PLC-board PL 100 B/PL 110 B
1st board: 460 mA& 25 mA
(all inputs and outputs open, 2nd board disconnected)
2nd board: 360 mA & 25 mA
recommended: R -Z 100 mS2 or max. lead length 10 m with a 4 mm2
cross-section
1 kV with a 1 MHz surge to IEC 255-4
Operation 0 . . . + 45’C (+ 32’F . . . + 113’F)
Storage - 30 . . . + 70°C (- 22’F . . + 158’F)
\
Operating panel: I P 54 I EC 529
Control TNC 151 B/TNC 151 0: 12 kg
Control TNC 155 B/TNC 1
9” VDU-BE 111: 6,8 kg
12” VDU-BE 211: 10 kg
12” VDU-BE 411: 10 kg
PLC-board PL 100 B/PL 1
see section 13
55 Q: 12 kg
Dimensions
OB: 1.2 kg
5

Table of Contents