8. Optimization of TNC 151ITNC 155-parameters
A provision for control adjustment is the checking procedure as per check lists 7.2.1 and 7.22 and the existence
of a PLCprogram. Adjustment takes place in accordance with the adjustment check list below:
8.1 Adjustment check list
Switch off buffer battery
0
--~-__
_I----
-
Determine machine traversing directions with
“right-hand-rule”
0
~- --.____ -__-_. ----_--
Entry of preliminary machine parameters
0
.--_-~
-_-_._-
Check traversing and counting directions of
individual axes and correct if necessary
0
-__-
Set range of software limit switches
0
~- ---
Offset adjustment
0
Adjustment of “linear characteristic”
0
--
Fine adjustment, trailing error and optimization
of positioning for
“linear characteristic”
0
____- .-
Adjustment of square root characteristic
0
Acceleration (linear and radial
j
-__- --I
Oscillation on acceleration for
“square root characteristic”
0
Approaching speed 1 pm before nominal position
for “square root characteristic”
Position s8upervision for “square root characteristic”
Integral factor X, Y, Z, IV
0
0
0
71