9.1  Dialogue  languages  for  customized  macros 
As  with  stalndard  dialogues,  customized  macros  can  also  be displayed  in  two  languages. 
The  entry  value  for  machine  parameter  MP 259  is added  to  the  dialogue  number  of  the  original 
language.  The  English  text  of  the  appropriate  dialogue  is stored  under  this  dialogue  number. 
Language  switchover 
259 
Difference  between  Q-numiber  of  dialogue 
for  customized  macros 
and  corresponding  translation 
Selection  -’  as to  whether  original  or  English  dialogue  -  automaticaliy  takes  place  s~imultaneously  to 
the  selection  of  the  plain  language  standard  dialogue  via  machine  parameter  MP 92. 
Example: 
Dialogues  fear customized  macro  “Bolt  hole  circle” 
0  Bolt  hole  circle 
1 Number  of  holes 
2  . . . 
10  Bolt  hole  circle 
11  Number  of  holes 
Entry  value  in  MP  259:  10 
9.2  Test  of  customized  macros 
Customized  macros  which  are  still  stored  within  the  NC-program  memory  can  also  be  recalled  via  PGM-call. 
For  testing,,  the  operating  mode  “Single  block”  is also  possible. 
9.3  Repetition  of  customized  macros 
Program  part  repeats  cannot  be executed  within  customized  macros  which  have  been  stored  within  the 
EPROM. 
Program  part  repeats  can  however,  be simply  programmed  via  Q-parameter  functions  (refer  to  the  following 
example  “Bolt  hole  circle”). 
88