Function
‘arameter
No.
Inhibited axes
72
Pre-cutout time for tapping cycle (onI\
effective with BCD-output of the
spindle speed)
Automatic operation:
Override with rapid
traverse button pressed
Feedrate override
Manual operation:
Override with rapid traverse button
pressed simultaneously
RPM-Override
Reference signal evaluation for
inhibited axes
-
Display and transducer
supervision for inhibited axes
either active or inactive
- Switch-off of transducer
supervision of uninhibited
or inhibited axes. The display
remains active.
PLC program from RAM
or from EPROM
RPM-range gear ratios
1 to8
S-Analogue output
~.
S-Analogue voltage with
S-Override at 100 %
S-Analogue voltage with
S-Override at max. output voltage
73
74
75
76
77
78 to 85
86
87
3 a
none
1 9 x-
2
c
y-
3 5 x-, Y-
4 & z-
5 g x-, z-
6 4 Y-, Z-
7 g x-, Y-, z-
8 c IV-
9 g x-, IV-
0 2 Y-, IV-
1 G x-, Y-, IV-
2 2 z-, IV-
3 : x-, z-,
IV-
4
f Y-, z-, IV-
5 A x-, Y-, z-, IV-
0 . . .
65.535 s
0 g inactive
1 2 active
add subsequent entry vailues depending on required
function
in 2 % -stages,
+ 2 c variable override
no override or
+ 4 e active override
in 2 % -stages, or
+ 8 g variable override
0 c No display “traverse to reference points” for
inhibited axes. If the position display of an
inhibited axis must count, the reference point
is to be traversed over.
1 2
“Traverse to reference points” is displayed for
inhibited axes
2 2 No display “traverse to reference points” for
inhibited axes. After a power interruption,
position display is set to 0 and counts although
reference points have not been approached.
0 2 inactive
1 =” active
add to 0 or 1:
+ 2 4 X without supervision
+ 4 c Y without supervision
+ 8 g Z without supervision
+16& IV without supervision
+322 V without supervision
0 2 RAM
1 4 EPROM
O...99999Crpm]
0. .9.999 CVJ
-.L
Entry values
99