13 Tables and Overviews
324
13.1 General User Parameters
Disabling the selection of file types
MP7224.0
All file types selectable via soft key: +0
Disable selection of HEIDENHAIN programs (soft key SHOW .H): +1
Disable selection of ISO programs (soft key SHOW .I): +2
Disable selection of tool tables (soft key SHOW .T): +4
Disable selection of datum tables (soft key SHOW .D): +8
Disable selection of pallet tables (soft key SHOW .P): +16
Disable selection of text files (soft key SHOW .A): +32
Disable selection of point tables (soft key SHOW .PNT): +64
Disabling the editor for certain file types
MP7224.1
Do not disable editor: +0
Disable editor for
■
HEIDENHAIN programs: +1
■
ISO programs: +2
■
Tool table: +4
■ Datum tables: +8
■
Pallet tables: +16
■
Text files: +32
■
Pallet tables: +64
Configure pallet files
MP7226.0
Pallet table inactive: 0
Number of pallets per pallet table: 1 to 255
Configure datum files
MP7226.1
Datum table inactive: 0
Number of datums per datum table: 1 to 255
Program length for program check
MP7229.0
Blocks 100 to 9 999
Program length up to which FK blocks are permitted
MP7229.1
Blocks 100 to 9 999
Dialog language
MP7230
English: 0 Swedish:7
German: 1 Danish:8
Czech: 2 Finnish:9
French: 3 Dutch:10
Italian: 4 Polish: 11
Spanish: 5 Hungarian: 12
Portuguese: 6
If a particular file type is inhibited, the
TNC will erase all files of this type.
Pkap13.pm6 30.06.2006, 07:04324
www.EngineeringBooksPdf.com