6 474 HEIDENHAIN Technical Manual TNC 426, TNC 430
7
77
7 When the current gain is properly adjusted, press the STORE MP2400.x soft
key to transfer the optimized value directly into the machine parameter.
7
77
7 Press the END key to exit the I CONTROL mode again.
MP2400 too large
MP2400 optimum
Max. 600 µs