Bench Mount Kit AT2000 CPK
Operating Instructions
Betriebsanleitung

Table of Contents

Questions and Answers

  • M
    Monique HumphreySep 12, 2025
    What to do if HellermannTyton Power Tool shows 'Time loss'?
    • W
      williamsjenniferSep 12, 2025
      If the HellermannTyton Power Tool displays 'Time loss', it indicates that the back-up battery in the power pack is dead. Replace the back-up battery and press the Reset button.
  • K
    Kurt MontoyaAug 25, 2025
    How to fix 'Error, front cap' on HellermannTyton AT2000 CPK bench mount kit Tools?
    • R
      Ronald RiddleAug 25, 2025
      If your HellermannTyton Tools display shows 'Error, front cap', it may be due to residues of cable ties trapped behind the front cap. Clean the front sensor. Another possible cause is a busy level sensor. If applicable, carefully remove any cable-tie residues.
  • R
    Richard HallAug 25, 2025
    What to do if HellermannTyton Tools display 'Error, gate'?
    • B
      Barbara ClayAug 26, 2025
      If your HellermannTyton Tools display shows 'Error, gate', it may be because the drum is not in the correct position. To resolve this, open the gate and turn the drum to the correct position. Alternatively, the gate may simply be open; in that case, close it.
  • S
    Sydney GraySep 23, 2025
    Why is binding not possible and the cable tie shoots straight out on my HellermannTyton Industrial Electrical?
    • P
      Paul HillSep 23, 2025
      If binding is not possible and the cable tie shoots straight out on your HellermannTyton Industrial Electrical, it means that the upper jaw is blocked. To fix this, check the upper jaw and remove any blockage.
  • B
    brendanbarberSep 13, 2025
    What to do if my HellermannTyton Industrial Electrical shows an overload error?
    • M
      Maxwell PrestonSep 13, 2025
      If your HellermannTyton Industrial Electrical unit displays an overload error, it could be due to several reasons. The drum might be blocked, the bandoleer cutter may not be cutting off the cable ties properly, or the cable tie bandoleer could be pulled in at an angle. To resolve this, push the actuator for the bandoleer cutter to the left, open the gate, and open the two service flaps at the gate. Remove any cable-tie residues, press the Reset button, and then close the gate.
  • R
    Robert GriffithSep 18, 2025
    What causes 'Error, front cap' on HellermannTyton Industrial Electrical?
    • C
      clinton43Sep 18, 2025
      The 'Error, front cap' message on your HellermannTyton Industrial Electrical can be caused by residues of cable ties trapped behind the front cap, or the level sensor being busy. To resolve this, clean the front sensor and carefully remove any cable-tie residues.
  • C
    Christine LeeSep 6, 2025
    What to do if HellermannTyton Power Tool displays 'Error, start position'?
    • M
      Michelle JacksonSep 6, 2025
      The 'Error, start position' message on the HellermannTyton Power Tool means it is not in the start position. Try the following: * Push the trigger for the bandoleer cutter to the left and open the gate. * Remove any cable-tie residues and press the Reset button. * Close the gate.
  • M
    Matthew GriffithSep 6, 2025
    What to do if the HellermannTyton Power Tool shows 'Overload'?
    • L
      Lisa McdanielSep 6, 2025
      If your HellermannTyton Power Tool displays 'Overload', it indicates that the drum is blocked or the cable tie is not cut off. You can: * Push the trigger for the bandoleer cutter to the left and open the gate. * Remove any cable-tie residues and press the Reset button.
  • C
    corey55Sep 23, 2025
    What does 'Error, binding force' mean on HellermannTyton Industrial Electrical?
    • L
      Laura BarnesSep 23, 2025
      The 'Error, binding force' message on your HellermannTyton Industrial Electrical means that the specified binding force is not being achieved. This message appears only if error notification is activated. To address this, check the binding, reset the binding force if applicable, remove any cable-tie residues, and press the trigger as confirmation.
  • H
    hendrixkimberlyAug 30, 2025
    What does 'Error, binding force' mean on HellermannTyton AT2000 CPK bench mount kit?
    • C
      Charles SmithAug 31, 2025
      If your HellermannTyton Tools display shows 'Error, binding force', the specified binding force is not being achieved. Check the binding.