Bench Mount Kit AT2000 CPK
Operating Instructions
Betriebsanleitung

Table of Contents

Questions and Answers

  • L
    lindsey25Sep 1, 2025
    Why am I experiencing time loss with my HellermannTyton AT2000 CPK bench mount kit Tools?
    • D
      Darrell MartinezSep 1, 2025
      If your HellermannTyton Tools are experiencing time loss, the back-up battery for the clock in the power pack has likely discharged. Change the back-up battery.
  • M
    Monique HumphreySep 12, 2025
    What to do if HellermannTyton Power Tool shows 'Time loss'?
    • W
      williamsjenniferSep 12, 2025
      If the HellermannTyton Power Tool displays 'Time loss', it indicates that the back-up battery in the power pack is dead. Replace the back-up battery and press the Reset button.
  • H
    hendrixkimberlyAug 30, 2025
    What does 'Error, binding force' mean on HellermannTyton AT2000 CPK bench mount kit?
    • C
      Charles SmithAug 31, 2025
      If your HellermannTyton Tools display shows 'Error, binding force', the specified binding force is not being achieved. Check the binding.
  • H
    Heather BurkeSep 14, 2025
    How to prevent loops from forming with HellermannTyton Industrial Electrical?
    • H
      Heather Robinson DVMSep 15, 2025
      Loops forming during the binding process with your HellermannTyton Industrial Electrical can be caused by several factors. It may be due to an unsuitable bundle diameter, the tie advancer not being in the correct position, a faulty spring in the upper jaw, or a blocked lower jaw. Here are some possible solutions: * Use a suitable bundle diameter. * Check the position of the tie advancer. * Check upper jaw flap in upper jaw with spring. * Check lower jaw and remove any blockage.
  • F
    fclarkSep 14, 2025
    Why does my HellermannTyton Industrial Electrical show an error, drum?
    • E
      Emily MullenSep 14, 2025
      The 'Error, drum' message on your HellermannTyton Industrial Electrical indicates that the cable tie bandoleer is pulled in at an angle, or the roller lever drum is jammed or defective. To fix this, push the actuator for the bandoleer cutter to the left and open the gate. Open the two transparent service flaps at the gate. Remove any cable-tie residues. Open the roller lever drum and turn the drum to the correct position. Then, press the Reset button and close the gate. Finally, load a new cable tie bandoleer.
  • R
    Robert GriffithSep 18, 2025
    What causes 'Error, front cap' on HellermannTyton Industrial Electrical?
    • C
      clinton43Sep 18, 2025
      The 'Error, front cap' message on your HellermannTyton Industrial Electrical can be caused by residues of cable ties trapped behind the front cap, or the level sensor being busy. To resolve this, clean the front sensor and carefully remove any cable-tie residues.
  • S
    Sydney GraySep 23, 2025
    Why is binding not possible and the cable tie shoots straight out on my HellermannTyton Industrial Electrical?
    • P
      Paul HillSep 23, 2025
      If binding is not possible and the cable tie shoots straight out on your HellermannTyton Industrial Electrical, it means that the upper jaw is blocked. To fix this, check the upper jaw and remove any blockage.
  • C
    Cynthia CurryAug 27, 2025
    What causes 'Error, start position' on HellermannTyton AT2000 CPK bench mount kit, and how can I fix it?
    • T
      Theresa ReynoldsAug 27, 2025
      If your HellermannTyton Tools display shows 'Error, start position', it may be because the AT2000 CPK is not in the start position. Push the actuator for the bandoleer cutter to the left. Other possible solutions include opening and closing the gate, carefully removing any cable-tie residues, and pressing the Reset button.
  • T
    tina81Aug 26, 2025
    How to troubleshoot 'Error, drum' on HellermannTyton AT2000 CPK bench mount kit Tools?
    • G
      Gabriel LinAug 26, 2025
      If your HellermannTyton Tools display shows 'Error, drum', it could be because the cable tie bandoleer is pulled in at an angle. Refer to the instructions for opening the two transparent flaps at the gate. Another possibility is that the roller lever drum is jammed or defective, in which case you should open the roller lever drum and turn the drum to the correct position.
  • R
    Richard HallAug 25, 2025
    What to do if HellermannTyton Tools display 'Error, gate'?
    • B
      Barbara ClayAug 26, 2025
      If your HellermannTyton Tools display shows 'Error, gate', it may be because the drum is not in the correct position. To resolve this, open the gate and turn the drum to the correct position. Alternatively, the gate may simply be open; in that case, close it.

HellermannTyton AT2000 CPK bench mount kit Specifications

General IconGeneral
BrandHellermannTyton
ModelAT2000 CPK bench mount kit
CategoryTools
LanguageEnglish