Users Manual Henkovac 04-serie V2019
6.0 Digital Control with LCD Display
Some Henkovac vacuum machines have a control system with just one Program (P1). Other machines
have an optional expanded control system, which can accommodate up to 9 custom programs (P1-9).
6.1 One-Program Control System
Henkovac machines with the One-Program control system
can be programmed for the following 2 functions:
1. Vacuum time (seconds)
2. Sealing time (seconds)
The values for vacuum and sealing times are selected by the user and saved in program P1
During operation, the LCD display will show symbols to indicate the active function and the pro-
gress of the packing cycle
The actual vacuum pressure is indicated by the analog vacuum gauge
Plug & Play
When turning on the machine for the first time:
o running time of the vacuum pump is pre-set at 30-40 seconds and the sealing time at
2 seconds. Vacuum is indicated on the analog vacuum gauge.
When turning on the machine after that, program P1 will contain the most-recently used settings
The vacuum and sealing times are easily adjusted to match the needs for the application