25
Standard Parameters
The following chart shows the parameters related to running a machine together with their
respective default values.
PARAMETER
MEANING
DEFAULT VALUE
Mixing – Time ON
Mixing – Time OFF
Mixing time ON
Mixing time OFF
1 min – 0 sec
120 min – 0 sec
Pumps – acceleration
Pump motor acceleration speed
1000
When the value increases
acceleration also increases
Pumps - deceleration
Pump motor deceleration speed
1500
When the value increases,
deceleration also increases
Pumps – Boost time
Time in which the pump motor
receives the maximum power
30 sec
Pumps – Start speed
Pump starting speed
15% (75 r.p.m.)
Canister Page
Dispensing speed
Pump dispensing speed
expressed as a percentage in
regards to the maximum value
60% (300 r.p.m.)
It is possible to set 60% (300
r.p.m. – 0,2 l/min)as a max value
when calibrating
Purging – ml
Ml to deliver during purging
1 ml
Purging - Speed
Pump speed during the purging
phase
25% (125 r.p.m.)
The above value corresponds to
the maximum speed of the step
motor torque
Drip-free device - Steps
Number of pump motor steps
during the phase in which the
drop is “pulled back”
40 (0,1 r. – 0,07 cc)
Drip-free device – Waiting time
Waiting time, after each dispense
has ended, before the drip-free
device phase is implemented
3 sec
Capacity
Canister capacity
2 litres