60
The horizontal resolution of far field measurement is listed below. User can select Standard or High Resolution mode from the web control page (see
Section 4.3)
Configuration Mode
Frame Rate
Horizontal Resolution of Far Field Measurement
Standard
10 Hz
0.2° for all channels
20 Hz
0.4° for all channels
High Resolution
10 Hz
0.1
°
for the 64 middle channels (Channel 27 to Channel 90)
0.2
°
for the other channels
NOTE
Channel # counts from 1 to 128
20 Hz
0.2° for the 64 middle channels (Channel 27 to Channel 90)
0.4° for the other channels
The horizontal resolution of near field measurement is always 0.4° at 10 Hz and 0. at 20 Hz