Hesai PandarQT - User Manual

Hesai PandarQT
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HESAI WeChat
www.hesaitech.com
Q01-en-2001A1
PandarQT
64-Channel Short-Range
Mechanical LiDAR
User Manual

Other manuals for Hesai PandarQT

Questions and Answers

  • B
    Brian MorrisonAug 19, 2025
    What to do if I can receive data on Wireshark but not on PandarView with Hesai Measuring Instruments?
    • E
      Eric VaughnAug 20, 2025
      If you're receiving data on Wireshark but not PandarView, ensure that the 'Destination IP' and 'Destination LiDAR Port' are correctly configured on the Settings page of the web control interface. Also, verify that the PC's firewall is disabled.
  • G
    Gary DoughertyAug 21, 2025
    What to do if the motor is running but no output data is received on Wireshark or PandarView from Hesai PandarQT?
    • J
      Jane BellAug 21, 2025
      If the motor runs but no output data is received, check these items: * Confirm the Ethernet cable is correctly connected. * Verify the IP configuration using Wireshark to ensure the LiDAR’s IP is in the same subnet as the PC’s. * Check the laser firing angle range and data generation settings on the Angle Range page of the web control. * Examine the sensor's firmware version on the Firmware Upgrade page of web control. If the version displays as “xxxx”, contact Hesai for diagnostics.
  • R
    Ryan MerrittAug 23, 2025
    Why can't I open web control for Hesai Measuring Instruments?
    • S
      Sara SmithAug 23, 2025
      If you cannot access the web control, verify that the Ethernet cable is properly connected. Also, confirm that the IP addresses for both the LiDAR and your PC are correct, using Wireshark if necessary. If issues persist, try restarting your PC or connecting the LiDAR to a different PC.
  • C
    Christina LittleAug 26, 2025
    What to do if I see abnormal point cloud on Hesai Measuring Instruments?
    • J
      James TaylorAug 26, 2025
      If you observe an abnormal point cloud with misaligned or flashing points, or an incomplete field of view (FOV), take the following steps: * Ensure the LiDAR’s enclosure is clean. If it is not, refer to Chapter 7 Sensor Maintenance for cleaning instructions. * Confirm the LiDAR’s calibration file is imported. Note that Pandar40P automatically imports the calibration file, while Pandar40 requires manual importing. * Check for packet loss. If no packets are missing but the point cloud flashes, update PandarView to the latest version and restart your PC. If the problem continues, try connecting the LiDAR to another PC.
  • R
    reedjacquelineAug 28, 2025
    What to do if I see abnormal packet size on Hesai Measuring Instruments?
    • D
      David Clark MDAug 28, 2025
      If you're experiencing abnormal packet sizes, which includes missing packets, check the following: * Verify if the FOV (field of view) has been changed on the Angle Range page of web control. * Check if the Ethernet is overloaded. * Determine if a switch is connected to the network, as data from other devices may cause network congestion and packet loss. * Connect the PC only to the LiDAR to check for packet loss.
  • S
    Stephanie MooreAug 29, 2025
    How to fix GPS lock issue on Hesai PandarQT?
    • M
      Manuel Burns DVMAug 29, 2025
      To resolve GPS lock issues, ensure the GPS receiver is properly connected and that the PPS signal is connected to the LiDAR. Verify the 'Destination GPS Port' is correct on the Settings page of web control. Also, confirm that the input GPS signals meet the electrical requirements specified in Section 2.2 Interface and Section 2.3.1 Connecting Box Interfaces of the user manual.
  • D
    Dr. David Miller DDSAug 31, 2025
    What to do if indicator light is off on the connection box of Hesai PandarQT?
    • M
      Margaret NelsonAug 31, 2025
      If the indicator light is off, ensure the power adapter is properly connected and in good condition. Also, check that the connection box is intact.
  • M
    Matthew HughesSep 3, 2025
    What to do if the motor is not running on Hesai PandarQT?
    • S
      Scott DavisSep 3, 2025
      If the motor is not running, make sure the power adapter is properly connected and in good condition and that the connection box is intact.
  • M
    mhaynesSep 4, 2025
    What to do if I can receive data on Wireshark but not on PandarView for Hesai Accessories?
    • T
      Tina BuckSep 4, 2025
      If you can receive data on Wireshark but not on PandarView, ensure that the Destination IP and the Destination LiDAR Port are set correctly on the Settings page of web control. Also, verify that the PC's firewall is disabled.
  • D
    Donald GarciaSep 6, 2025
    Why is the motor running but no output data is received on Wireshark or PandarView from my Hesai Accessories?
    • C
      Catherine MorenoSep 7, 2025
      If the motor is running but no output data is received on either Wireshark or PandarView, ensure that the Ethernet cable is properly connected. Also, check the IP configuration by using Wireshark to get the LiDAR's IP and ensure it's in the same subnet as the PC's. Check the angle range of laser firing and data generation on the Azimuth FOV page of web control. Finally, check the firmware version of the sensor on the Upgrade page of web control. If the version is not shown properly but as "xxxx", contact Hesai for further diagnostics.

Summary

Safety Notice

General Safety Warnings

General safety precautions and warnings for device operation and handling.

Laser Safety Classification

Details on the device's Class 1 laser safety compliance and guidelines.

Operational Safety Precautions

Device Handling, Environment & Interference

Precautions for handling, environment, interference, and physical safety.

Introduction

1.4 Specifications

Lists the technical specifications for the PandarQT LiDAR.

Setup

2.1 Mechanical Installation

Provides guidance on physical installation methods and mounting.

Installation Methods

Details recommended and side installation procedures for the LiDAR.

2.2 Interfaces

Describes the connector types and pin assignments for data and power connections.

Connector Pinouts and Cables

Details the 4-pin and 8-pin socket pinouts and relevant cable specifications.

2.4 Get Ready to Use

Steps to configure the PC and prepare for receiving LiDAR data.

Data Structure

3.1 Point Cloud Data Packet

Describes the structure of point cloud data packets.

3.1.3 Point Cloud Data Analysis

Explains how to analyze point cloud data for angles and distance.

3.2.3 GPS Data Analysis

Explains how to analyze GPS data by parsing NMEA messages like GPRMC and GPGGA.

Web Control

4.2 Settings - IP and Functions

Configuration of IP settings and LiDAR functions like return mode and UDP sequence.

4.2 Settings - Trigger, Standby & Reset

Configuration of trigger methods, standby mode, and resetting settings to defaults.

4.2 Settings - Clock Source and PTP

Configuration of clock source and PTP parameters for time synchronization.

Communication Protocol

6.1 Packet Structure

Describes the format of command and feedback messages exchanged with the LiDAR.

6.2 Frequently Used Commands

Lists common commands for retrieving calibration, diagnostics, and status information.

Sensor Maintenance

Troubleshooting

Troubleshooting Guide (Part 1)

Common issues and points to check for indicator lights, motor, and data output problems.

Troubleshooting Guide (Part 2)

Additional troubleshooting for abnormal point clouds and GPS locking issues.

Appendix I: Absolute Time and Laser Firing Time

Appendix II: PTP Protocol

Hesai PandarQT Specifications

General IconGeneral
Weight< 0.91 kg
Laser Wavelength905 nm
Field of View (Vertical)70.4°
Angular Resolution (Vertical)0.2°
Angular Resolution (Horizontal)0.2°
Operating Voltage9-36 VDC
Accuracy±2 cm
Protection LevelIP67
Power Consumption (typical)12 W
Ingress Protection RatingIP67
Points per Second768, 000 pts/s