EasyManua.ls Logo

Hesai PandarQT User Manual

Hesai PandarQT
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HESAI WeChat
www.hesaitech.com
Q01-en-2001A1
PandarQT
64-Channel Short-Range
Mechanical LiDAR
User Manual

Other manuals for Hesai PandarQT

Questions and Answers:

Hesai PandarQT Specifications

General IconGeneral
Weight< 0.91 kg
Laser Wavelength905 nm
Field of View (Vertical)70.4°
Angular Resolution (Vertical)0.2°
Angular Resolution (Horizontal)0.2°
Operating Voltage9-36 VDC
Accuracy±2 cm
Protection LevelIP67
Power Consumption (typical)12 W
Ingress Protection RatingIP67
Points per Second768, 000 pts/s

Summary

Safety Notice

General Safety Warnings

General safety precautions and warnings for device operation and handling.

Laser Safety Classification

Details on the device's Class 1 laser safety compliance and guidelines.

Operational Safety Precautions

Device Handling, Environment & Interference

Precautions for handling, environment, interference, and physical safety.

Introduction

1.4 Specifications

Lists the technical specifications for the PandarQT LiDAR.

Setup

2.1 Mechanical Installation

Provides guidance on physical installation methods and mounting.

Installation Methods

Details recommended and side installation procedures for the LiDAR.

2.2 Interfaces

Describes the connector types and pin assignments for data and power connections.

Connector Pinouts and Cables

Details the 4-pin and 8-pin socket pinouts and relevant cable specifications.

2.4 Get Ready to Use

Steps to configure the PC and prepare for receiving LiDAR data.

Data Structure

3.1 Point Cloud Data Packet

Describes the structure of point cloud data packets.

3.1.3 Point Cloud Data Analysis

Explains how to analyze point cloud data for angles and distance.

3.2.3 GPS Data Analysis

Explains how to analyze GPS data by parsing NMEA messages like GPRMC and GPGGA.

Web Control

4.2 Settings - IP and Functions

Configuration of IP settings and LiDAR functions like return mode and UDP sequence.

4.2 Settings - Trigger, Standby & Reset

Configuration of trigger methods, standby mode, and resetting settings to defaults.

4.2 Settings - Clock Source and PTP

Configuration of clock source and PTP parameters for time synchronization.

Communication Protocol

6.1 Packet Structure

Describes the format of command and feedback messages exchanged with the LiDAR.

6.2 Frequently Used Commands

Lists common commands for retrieving calibration, diagnostics, and status information.

Sensor Maintenance

Troubleshooting

Troubleshooting Guide (Part 1)

Common issues and points to check for indicator lights, motor, and data output problems.

Troubleshooting Guide (Part 2)

Additional troubleshooting for abnormal point clouds and GPS locking issues.

Appendix I: Absolute Time and Laser Firing Time

Appendix II: PTP Protocol

Related product manuals