DC2000 – Installation Manual 10
HHO Plus, Alternative Energies, Lta – Travessa das Serras 33, Vieira de Leiria, Portugal – Tel. 00351244697116 – Email: info@hhhoplusgas.com
Positioning the water and HHO hoses
The hose connections on vertical position of the dry-cell do not require any special remarks. The water
intake is connected in the bottom and HHO output will be in the top of the cell. You just need to make sure
that the HHO output hose is always above the top of the cell. If not the HHO gas will have difficulties moving
outside the cell and the production will be reduced.
The hose connections on horizontal position of the dry-cell require only that the positioning of the HHO
output hose be made also always on an uprising position without ups and downs. If this happens, the HHO
gas will have problems moving into the water tank and will also be released gulps reducing the efficiency of
the system. You may verify this problem if fluctuation of the amperage on your system is very high. Please
refer to the illustration below for typical installation of the hoses coming and going from the water tank: