EasyManua.ls Logo

HHO Plus DC2000 - Page 7

HHO Plus DC2000
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC2000 Installation Manual 7
HHO Plus, Alternative Energies, Lta Travessa das Serras 33, Vieira de Leiria, Portugal Tel. 00351244697116 Email: info@hhhoplusgas.com
Make sure to install the Dry-Cell in a place that can easily be accessed
and cleaned or inspected from time to time. It should be mounted and
secured in such a manner as to ensure it does not move or bounce
around while the vehicle is in motion, even over rough terrain.
Securing it with a permanent metal bracket (see photos above metal
bracket not included in the kit) should be sufficient to secure it to the
engine chassis and to operate perfectly.
The dry-cell can be mounted in horizontal
or vertical position.
The vertical position does not require any special remarks. The water
intake is connected in the bottom and HHO output will be in the top
of the cell. You just need to make sure that the HHO output hose is always above the top of the cell. If not the
HHO gas will have difficulties moving outside the cell and the production will be reduced.
The horizontal position requires more care in the installation. The cell has to be positioned upright and
leveled to the ground with the tube fittings facing directly to the sky. If you look carefully the cell has 2
openings, one higher than the other. The lower opening is for the water intake and the upper opening for
HHO gas output. We must make sure that the cell is not placed with an angle/rotation that reduces the
distance between the two openings. Please take a look at the pictures below.
If the Dry-Cell is placed as shown in the image on the right you will not use 100% capacity of the generator to
produce HHO gas. Also the HHO gas will have problems getting out of the cell being released gulps. You can
verify this problem if fluctuation of the amperage is very high.
Important Information:
When making the installation
never make any type of
changes in the dry-cell.
Never open it, loosen/tighten
the nuts or cut the screws.
You will damage the dry-
cell and it will not work
properly after. Changes
made in the cell are not
covered by the warranty.