VertX V1000 (CS) Quick Installation Guide
CAUTION: During the process of rebooting the controller, all network configuration information will
be overwritten and returned to the original defaults.
4. Configure the controller for your installation parameters. See 3.1 VertX Communications, page 12.
Firew all
If the VertX controller is being installed where it communicates through a firewall, then the firewall may need
to be configured to allow TCP data transfer on the specified port(s).
1. Before starting, ensure that any pop-up blocker software is disabled on the computer.
2. Open the following ports on the firewall.
TCP outbound.connection_port (4070) This port must be open on the Host
computer.
listen_port (4050) TCP incoming. This port must be open when using selected
applications. See the Central Station for information.
If you are not familiar with configuring a firewall for a network, contact the Network/IT administrator or
manager.
CAUTION: If the firewall is not configured properly the controller may not communicate with the host.
Cent r al St at ion Aut om a t ion Pr oviders
Central Station Automation Software Here I am Interval
Dice Corporation 60
Bold Technologies 60
Micro Key Software 3600
Patriot Systems Pending
Here I am IntervalPerform the following steps if the central station requires the to change.
1. Open your Internet Browser.
Address field. 2. Enter the V1000 IP address or host name into the
3. Click
.
4. Change the Here I am Interval 0 from (default) to the new parameter.
5. Click Submit and the change will become activated once the controller is rebooted.
6. Close the browser window(s) when completed.