EasyManua.ls Logo

HiDew DDS - Technical Data: DOS Models (070-230); DOS 070-100 Specifications; DOS 160-230 Specifications

HiDew DDS
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
rev08- Installation, use and maintenance manual
DDS-DCS-DVS-DOS - Dehumidifiers for small swimming pools
26 - 60
4.3 DOS TECHNICAL DATA TABLES
MODEL
um
070
090
100
Dehumidification capacity
L/day
67
92
99
Nominal air flow
m
3
/h
600
700
800
Useful static head
Pa
200
175
150
Sound pressure
dB(A)
46
47
48
Hot water coil power
kW
6.1
6.8
7.5
Water coil pressure drops with valve
kPa
33
40
47
Electrical power supply
V/ph/Hz
230/1+N/50
230/1+N/50
230/1+N/50
Electrical heaters capacity
kW
2
3
3
Nominal compressor power
kW
0.85
1.37
1.37
Nominal compressor current
A
3.89
6.37
6.37
Nominal unit power
kW
0.93
1.47
1.65
Maximum unit power
kW
1.36
2.02
2.18
Nominal unit current
A
4.6
7.1
8.6
Maximum unit current
A
6.6
9.7
11
Peak unit current
A
20
37.3
38.6
Maximum unit current with resistances
A
15.3
22.8
24.1
Peak unit current with resistances
A
28.7
50.3
51.6
Dimensions (base x depth x height)
mm
1105 x 800 x 410
1105 x 800 x 410
1105 x 800 x 410
Weight
Kg
84
84
84
Refrigerant
type
R410A
R410A
R410A
MODEL
um
160
190
210
230
Dehumidification capacity
L/day
161
182
213
225
Nominal air flow
m
3
/h
1000
1200
1500
1500
Useful static head
Pa
230
200
150
150
Sound pressure
dB(A)
50
52
53
54
Hot water coil power
kW
10.4
11.9
13.3
13.3
Water coil pressure drops with valve
kPa
34
44
55
55
Electrical power supply
V/ph/Hz
230/1+N/50
230/1+N/50
400/3+N/50
400/3+N/50
Electrical heaters capacity
kW
4
4
4
4
Nominal compressor power
kW
2
2.49
3.15
3.24
Nominal compressor current
A
9.1
11.5
5.9
6.1
Nominal unit power
kW
2.19
2.74
3.48
3.57
Maximum unit power
kW
3.27
3.53
4.97
5.03
Nominal unit current
A
10.6
13.5
8.4
8.6
Maximum unit current
A
16.3
17.7
11.1
11.2
Peak unit current
A
57.6
65.6
51.6
51.6
Maximum unit current with resistances
A
33.7
35.1
19.8
19.9
Peak unit current with resistances
A
75
83
60.3
60.3
Dimensions (base x depth x height)
mm
1105 x 1050 x 510
1105 x 1050 x 510
1105 x 1050 x 510
1105 x 1050 x 510
Weight
Kg
147
147
168
168
Refrigerant
type
R410A
R410A
R410A
R410A
The dehumidification power is declared in the nominal point 30° C/80% RH
The currents and the absorbed powers are declared in the nominal point 30°C/80% RH
The power of the hot water coil is declared with ambient air at 30°C and water in 80°C and out 70°C
The sound pressure is measured at 1 meter in free field
In different conditions the declared values will undergo variations which can also be very important, the further away from the
nominal operating conditions.

Related product manuals